Accueil> Blog> Key technology for installation of pipeline centrifugal pump: pump installation height is suction selection

Key technology for installation of pipeline centrifugal pump: pump installation height is suction selection

June 28, 2023

First, the key installation technology of centrifugal pump

The key to the installation technology of the pipeline centrifugal pump is to determine the installation height of the pump (ie suction stroke). This height refers to the vertical distance from the water source to the centerline of the pump impeller. It is not to be confused with the allowable vacuum height. The allowable vacuum height indicated on the pump product specification or on the nameplate refers to the vacuum value on the pump inlet section. The test was carried out under the conditions of 1 standard atmospheric pressure and a water temperature of 20 degrees Celsius. It does not take into account the flow of water after the suction pipe is fitted. The installation height of the pump should be the value of the remaining part that allows the suction vacuum height to be deducted from the loss of the suction pipe. It must overcome the actual terrain water absorption height. The pump installation height cannot exceed the calculated value, otherwise the pump will not be able to pump water. In addition, the magnitude of the influence calculation value is the resistance loss head of the suction pipe. Therefore, it is advisable to use the short piping arrangement of the Zui, and to install accessories such as elbows as little as possible. It is also conceivable to properly fit the water pipes with a larger diameter to reduce the flow velocity inside the pipe.

It should be pointed out that when the elevation and water temperature of the installation place of the pipeline centrifugal pump are different from the test conditions, such as the local altitude above 300 meters or the water temperature of the pumped water exceeds 20 degrees Celsius, the calculated value should be corrected. That is, the atmospheric pressure at different elevations and the saturated vapor pressure above 20 degrees Celsius. However, when the water temperature is below 20 degrees Celsius, the saturated vapor pressure is negligible.

From the pipeline installation technology, the suction pipe requires strict sealing, and it cannot leak or leak water. Otherwise, the vacuum at the water inlet of the pump will be destroyed, so that the water output of the pump will be reduced, and even if it is serious, the water will not be pumped. Therefore, it is necessary to carefully do the interface work of the pipeline to ensure the construction quality of the pipeline connection.

Second, the installation height of the centrifugal pump Hg calculation

Allowing the suction vacuum height Hs means that the pressure p1 at the pump inlet can be allowed to reach a large vacuum.
The actual allowable vacuum height Hs value is not a value calculated according to the formula, but a value determined experimentally by the pump manufacturer. This value is attached to the pump sample for the user to check. It should be noted that the Hs value given in the pump sample is the value when the water is used as the working medium, the operating conditions are 20 ° C and the pressure is 1.013 × 105 Pa. When the operating conditions and working medium are different, the conversion is required.

(1) Conveying clean water, but the operating conditions are different from the experimental conditions, and can be converted according to the following formula: Hs1=Hs+(Ha-10.33) - (Hυ-0.24)

(2) Conveying other liquids When the conditions of the liquid to be transported and the villain are different from the experimental conditions, a two-step conversion is required: * step according to the above formula will be Hs1 detected by the pump sample; second step will be converted according to the following formula: Hs1 Into H?s

2 NPSH Δh

For the oil pump , calculate the installation height with the NPSH Δh, that is, the vacuum that the pump allows to absorb the liquid, that is, the allowable installation height of the pump, in meters. The NPSH Δh was taken from the oil pump sample and its value was also measured with 20 ° C water. If other liquids are transported, corrections are also required. Check the relevant books.

Suction stroke = standard atmospheric pressure (10.33 m) - NPSH - safety (0.5 m)
The standard atmospheric pressure energy pipeline has a vacuum height of 10.33 meters.
For example: a pump must have a NPSH of 4.0 meters, and ask for a suction Δh?
Solution: Δh=10.33-4.0-0.5=5.83 m

From a safety point of view, the actual installation height of the pump should be less than the calculated value. When the calculated Hg is negative, the pump's suction port position should be below the tank level.

Example 2-3 A centrifugal pump was found to allow the vacuum height Hs = 5.7 m from the sample. It is known that the total resistance of the suction line is 1.5 mH2O, the local atmospheric pressure is 9.81 x 104 Pa, and the dynamic head of the liquid in the suction line is negligible. Trial calculation:
(1) Installation of the pump when conveying 20°C clean water;
(2) The installation height of the pump when transporting water at 80 °C.

Solution: (1) The installation height of the pump is known to deliver 20°C clean water: Hs=5.7m
Hf0-1=1.5m
U12/2g≈0
The local atmospheric pressure is 9.81×104Pa, which is basically consistent with the experimental conditions when the pump is shipped, so the installation height of the pump is Hg=5.7-0-1.5=4.2 m.

(2) Mounting height of the pump when transporting 80°C water

When transporting water at 80 °C, the installation height cannot be calculated directly from the Hs value in the pump sample. It is necessary to convert the Hs according to the following formula, ie Hs1=Hs+(Ha-10.33) - (Hυ-0.24)

It is known that Ha = 9.81 × 104 Pa ≈ 10 mH 2 O, and the saturated vapor pressure of water at 80 ° C was found to be 47.4 kPa by the appendix.
Hv=47.4×103 Pa=4.83 mH2O
Hs1=5.7+10-10.33-4.83+0.24=0.78m

Substituting the Hs1 value into the formula to obtain the installation height Hg=Hs1-Hf0-1=0.78-1.5=-0.72m
Hg is a negative value, indicating that the pump should be installed below the pool level, at least 0.72m below the liquid level.

Key technology for installation of pipeline centrifugal pump: pump installation height is suction selection 2007-8-8
Chemical pump overview 2007-8-14
Vacuum pump overview 2007-8-14
Sewage pump overview 2007-8-14
Centrifugal pump overview 2007-8-14
Clean water pump overview 2007-8-14
Fire pump product overview 2007-8-14
Oil pump overview 2007-8-14
Water supply equipment overview 2007-8-14
Screw pump working principle 2007-8-16
Vortex pump working principle 2007-8-16
Magnetic pump working principle 2007-8-16
Axial flow pipeline pump working principle flash animation 2007-8-16
Centrifugal pump working principle flash animation 2007-8-16
Maintenance and maintenance of submersible sewage pump 2007-8-16
Pump selection principle, basis and specific operation mode 2007-8-16
Global energy crisis, ground source heat pump into a new favorite of building energy conservation 2007-8-16
Diaphragm pump working principle 2007-8-16
Gear pump working principle 2007-8-16
Basic knowledge of the pump 2007-8-16
Selection of fire pump 2007-8-16
Common knowledge of water ring vacuum pump 2007-8-17
Self-priming pump knowledge 2007-8-19
Pump knowledge 2007-8-19
Water ring vacuum pump working principle 2007-8-9
Application of screw pump in sewage treatment process 2007-8-16
Discussion on fire hydrant system and fire pump 2007-8-16
Structural characteristics of magnetic pump and its use and maintenance 2007-8-16
Selection of single screw pump 2007-8-16
What is the working principle of the self-priming pump? 2007-8-19
Diaphragm pressure tank 2007-8-21
Centrifugal pump selection 2007-8-22
Chemical pump material selection 2007-8-22
What is the working fluid of the jet vacuum pump? What are the advantages of a jet vacuum pump? 2007-8-16
Application analysis of submersible sewage pump in engineering 2007-8-16
About the installation requirements and technical improvements of the FY type submerged pump 2007-8-9
What is the cavitation of the pump? 2007-8-9
Pipeline pump selection 2007-8-16
Self-priming pump type installation and precautions 2007-8-16
Screw pump standard summary 2007-8-22
Product overview of automatic water supply equipment without negative pressure (no suction) 2007-8-16
Rotary vane vacuum pump 2007-8-17
Current status, development trend and design of water ring vacuum pump 2007-8-17
Rotary vane vacuum pump working principle 2007-8-23
Submerged pump selection
Nous contalit

Auteur:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Produits populaires
Vous pouvez aussi aimer
Catégories connexes

Envoyer à ce fournisseur

Sujet:
E-mail :
message:

Votre message MSS

Nous contalit

Auteur:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Produits populaires

Accueil

Product

Whatsapp

À propos de nous

Demande

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

envoyer