Suzhou Macxi Fluid Technology Co.,Ltd.
Accueil> Blog> Tiancheng special pump centrifugal pump adjustment method

Tiancheng special pump centrifugal pump adjustment method

October 30, 2022

Centrifugal pump operating point, is the intersection of pump characteristic curve and pipeline characteristic curve. Artificial changes to the pump operating conditions point method, called the pump regulation. There are only two ways to change the working point of the centrifugal pump: one is to change the pump characteristic curve and the other is to change the pipeline characteristic curve.

(1) change the pump characteristic curve to adjust:
① change speed control pump performance;
② turning impeller diameter, expanding the scope of use;
③ remove the impeller series, multi-stage pump impeller can be removed by the series, to achieve the purpose of adjusting the head.
(2) to change the pipeline characteristic curve to adjust:
① outlet valve closure regulation;
② by-pass valve to adjust.

Nous contalit

Auteur:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Produits populaires
Vous pouvez aussi aimer
Catégories connexes

Envoyer à ce fournisseur

Sujet:
E-mail :
message:

Votre message MSS

Nous contalit

Auteur:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

Produits populaires

Accueil

Product

Whatsapp

À propos de nous

Demande

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

envoyer